Enhanced Oil Recovery EOR Systems and Facilities by EN-FAB Inc

0
306

Enhanced Oil Recovery EOR Systems and Facilities 
EN-FAB Inc provides advanced enhanced oil recovery EOR systems and facilities to maximize hydrocarbon recovery and extend reservoir life with proven engineering solutions.

Feed water Pump and Prime Mover

The feed water pump is normally a positive displacement pump to provide the necessary feed water pressure and flow rate required for the generator.

Feed water Preheater

This is normally a double pipe hair pin type heat exchanger used to raise the feed water temperature above the flue gas dew point to prevent condensation of water in the flue gas and the resulting acid corrosion and deposits.

Radiant Section

The radiant section is cylindrical with horizontal tubes transposed around the radiant section for equalized heat pick up. The tubes are supported with high alloy tube supports and are free to expand with temperature changes. The radiant section also provides large furnace volume for flexibility in combustion fuel and firing changes. The heat transfer surface in the radiant section normally picks up about 60% to 65% of the overall heat transfer duty. The refractory lined wall provides for reflective heat transfer to the tubes and insulation to reduce heat loss through the chamber wall.

Convective Section

The convection section is fabricated from both bare and extended surface tubes. Flue gases from the radiant section enters the convective section flowing across the bare or shock tubes first and then across the extended surface tubes. The convective section normally picks up 35% of 40%, or more, of the overall heat transfer duty. These convective sections are designed to give the desired efficiencies. Mechanically they are designed for easy tube replacement and maintenance. Side covers may be supplied with lay down doors for cleaning if desired.

Burner

Burners may be supplied for natural gas, butane, propane, or liquid fuels. Liquid fuels include crude oil. Heavy viscous oils need preheating to provide a viscosity at the burner of 100 to 150 SSU's at the burner nozzle.

Controls

The feed water flow rate is controlled by the generator discharge pressure. The burner firing rate is controlled by a metered flow rate signal. This allows the generator to be adjusted to give the desired steam discharge quality. Standard and optional safety limit devices allow unattended operation of the Generator. Certain limits are standard with annunciator lights to indicate reason of shutdown. Other limits are optional along with additional annunciator devices.

البحث
الأقسام
إقرأ المزيد
Karadeniz Genel
Pune Realty Boom 2026: Top Residential & Commercial Projects in Hinjewadi, Wakad & Beyond
Pune Realty real estate landscape is evolving rapidly, especially across emerging corridors like...
بواسطة gupta084 2026-03-27 09:05:11 0 789
💔 Aşk & İlişkiler
ꃄꄱ꓅⌯Call Girls In Janpath Metro ⏭97110≈14705⏮ Delhi ⇎ NCR
Call Girls In Delhi Contact Us ➥ 𝟗𝟕𝟏𝟏𝟎𝟏𝟒𝟕𝟎𝟓 ➥ (Low Price) Escorts Provide In Delhi High Profile...
بواسطة sharmaneeta 2026-08-10 11:58:09 0 52
🏞️ Karadeniz Türizm
Kış Aylarında Karadeniz Tatili: Kar Manzarası, Sessizlik ve Doğa
Karadeniz denince akla genellikle yaz ayları, yeşil yaylalar ve serin hava gelir. Ancak kış...
بواسطة Karadeniz 2025-12-21 23:28:05 0 1كيلو بايت
🎭 Kültür & Sanat
Density of Embroidery Stitches: A Complete Guide for Better Results
Density of Embroidery Stitches Introduction Have you ever embroidered a design that looked...
بواسطة henryphilip 2026-06-12 14:15:13 0 427
📍 Karadeniz Şehirleri
Expert Pest Control Services for Homes & Businesses
Pest Control Gerrards Cross  Pests can become a major concern for homeowners and...
بواسطة RatticPestControl 2026-07-25 02:46:48 0 60